6 resultados para Platelet Membrane Glycoproteins

em Cochin University of Science


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new PVC membrane sensor, which is highly selective towards Ni (II) ions, has been developed using a thiophene-derivative Schiff base as the ionophore. The best performance was exhibited by the membrane having the composition percentage ratio of 5:3:61:31 (ionophore:NaTPB:DBP:PVC) (w=w), where NaTPB is the anion excluder, sodium tetraphenylborate and DBP is the plasticizing agent (dibutyl phthalate). The membrane exhibited a good Nernstian response for nickel ions over the concentration range of 1.0 10 1– 5.0 10 6M (limit of detection is 1.8 10 6 M) with a slope of 29.5 1.0mV per decade of activity. It has a fast response time of<20 s and can be used for a period of 4 months with good reproducibility. The sensor is suitable for use in aqueous solutions of a wide pH range of 3.2–7.9. The sensor shows high selectivity to nickel ions over a large number of mono-, bi- and trivalent cations. It has been successfully used as an indicator electrode in the potentiometric titration of nickel ions against EDTA and also for direct determination of nickel content in real samples – wastewater samples from electroplating industries and Indian chocolates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new PVC membrane sensor, which is highly selective towards Ni (II) ions, has been developed using a thiophene-derivative Schiff base as the ionophore. The best performance was exhibited by the membrane having the composition percentage ratio of 5:3:61:31 (ionophore:NaTPB:DBP:PVC) (w=w), where NaTPB is the anion excluder, sodium tetraphenylborate and DBP is the plasticizing agent (dibutyl phthalate). The membrane exhibited a good Nernstian response for nickel ions over the concentration range of 1.0 10 1– 5.0 10 6M (limit of detection is 1.8 10 6 M) with a slope of 29.5 1.0mV per decade of activity. It has a fast response time of<20 s and can be used for a period of 4 months with good reproducibility. The sensor is suitable for use in aqueous solutions of a wide pH range of 3.2–7.9. The sensor shows high selectivity to nickel ions over a large number of mono-, bi- and trivalent cations. It has been successfully used as an indicator electrode in the potentiometric titration of nickel ions against EDTA and also for direct determination of nickel content in real samples – wastewater samples from electroplating industries and Indian chocolates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present study we assessed plasma and platelet monoamine content using high performance liquid chromatography (HPLC). The study included 22 subjects consisting of 12 freshly-detected male diabetic patients and 10 age and sex-matched healthy controls. The same parameters were measured in streptozotocin -induced diabetic rat models consisting of controls , diabetic and insulin - treated diabetic rats. The platelet counts were significantly reduced (P < 0.05) in rat models as well as human diabetic samples. The plasma norepinephrine (NE) and epinephrine (EPI) concentrations were significantly increased (P < 0.05). The platelet showed a significant increase (P < 0.01) in NE, EPI and serotonin content. Increase in the plasma and platelet content of neurotransmitters may be due to increased sympathetic function, which is an adaptation for the decreased platelet count observed in our study . The results indicate that changes in the neurotransmitter content of the platelet may be a good index to assess the neurotransmitter status in pathological condition such as diabetes mellitus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PVC supported liquid membrane and carbon paste potentiometric sensors incorporating an Mn(III)-porphyrin complex as a neutral host molecule were developed for the determination of paracetamol. The measurements were carried out in solution at pH 5.5. Under such conditions paracetamol exists as a neutral molecule. The mechanism of molecular recognition between the Mn(III)-porphyrin and paracetamol, leading to potentiometric signal generation, is discussed.The sensitivity and selectivity toward paracetamol of carbon paste and polymeric liquid membrane electrodes incorporating an Mn(III)-porphyrin host were compared. The applicability of these sensors to the direct determination of paracetamol was checked by performing a recovery test in human plasma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fulminant hepatic failure (FHF) is a dramatic and challenging syndrome in clinical medicine. Although an uncommon disorder, it is usually fatal and occurs in previously healthy person. While the causes of FHF remain unclear, viral hepatitis and drug-induced liver injury account for the majority of cases. Hepatitis E causes large-scale epidemics of hepatitis in the Indian subcontinent, involving hundreds of thousands of cases with high mortality. FHF is associated with several clinical features like jaundice, shrunken liver, easy bruising, low levels of serum proteins, fatigue, multi-organ failure etc and metabolic derangements like hypoglycemia, hyperlipidemia, hyponatremia, defective protein synthesis, reduced energy production, decreased rate of urea production etc. These disturbances are predominantly attributed to oxidative stress, membrane destabilization and osmolytic imbalances. The options available for these patients are quite minimal with liver transplantation being one of them. But the procedure is ridden with issues causing it to find less favor among the patients and the caregivers. Use of hepatoprotective and cytoprotective drugs, is being considered to be a more acceptable alternative as a strategy to enhance liver regeneration. In this regard use of taurine a naturally occurring amino acid that plays a crucial role in many physiological processes would prove to be effective. In the present study, hepatoprotective effect of taurine on a rat model of induced FHF was studied. Taurine supplementation has effectively counteracted the metabolic and structural aberrations in the liver caused by D-galactosamine intoxication.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present thesis develops from the point of view of titania sol-gel chemistry and an attempt is made to address the modification of the process for better photoactive titania by selective doping and also demonstration of utilization of the process for the preparation of supported membranes and self cleaning films.A general introduction to nanomaterials, nanocrystalline titania and sol-gel chemistry are presented in the first chapter. A brief and updated literature review on sol-gel titania, with special emphasis on catalytic and photocatalytic properties and anatase to rutile transformation are covered. Based on critical assessment of the reported information the present research problem has been defined.The second chapter describes a new aqueous sol-gel method for the preparation of nanocrystalline titania using titanyl sulphate as precursor. This approach is novel since no earlier work has been reported in the same lines proposed here. The sol-gel process has been followed at each step using particle size, zeta potential measurements on the sol and thermal analysis of the resultant gel. The prepared powders were then characterized using X-ray diffraction, FTIR, BET surface area analysis and transmission electron microscopy.The third chapter presents a detailed discussion on the physico-chemical characterization of the aqueous sol-gel derived doped titania. The effect of dopants such as tantalum, gadolinium and ytterbium on the anatase to rutile phase transformation, surface area as well as their influence on photoactivity is also included. The fourth chapter demonstrates application of the aqueous sol-gel method in developing titania coatings on porous alumina substrates for controlling the poresize for use as membrane elements in ultrafiltration. Thin coatings having ~50 nm thickness and transparency of ~90% developed on glass surface were tested successfully for self cleaning applications.